PV String Input Data |
1 |
Maximum PV Power at STC (Standard Test Condition) |
8.8 KWp |
2 |
Recommended PV Power at STC (Standard Test Condition) |
6.6-8.8 KWp |
3 |
Vmax PV (absolute maximum) (V) |
1000 V |
4 |
MPPT Range (V) |
80-800 V |
5 |
MPPT Range for Full Load (V) |
200-800 V |
6 |
Start-up Voltage (V) |
Settable (100-500 V) |
7 |
Nominal Input DC Voltage (V) |
500 V |
8 |
Max. continuous input current (A) |
17 A (per PV string) |
9 |
Isc PV (absolute maximum short circuit current) (A) |
20 A (per PV string) |
10 |
No. of MPP Trackers |
2 |
11 |
No. of Inputs Strings per Tracker |
1 |
12 |
Maximum Backfeed Current (A) |
0 A |
AC Output Data |
1 |
Rated Output Power (W) |
6.6 KW |
2 |
Maximum Output Apparent Power (KVA) |
8.8 KVA (@ maximum grid voltage of 460 (1-1) V) |
3 |
Nominal Output Voltage/ Range (V) |
415/(350 - 460) V |
4 |
Nominal Output Frequency/ Range (Hz) |
50/(47.5 - 52) Hz |
5 |
Max. Continuous Output Current (A) |
11 A (per phase) |
6 |
Current Inrush at inverter start-up (A) |
15 A (peak) |
7 |
Output Power Factor |
Default Unity (Adjustable from 0.8 leading to 0.8 lagging) |
8 |
Output THD (@ Nominal Output Power and Voltage) |
< 2.5% |
9 |
Active Power Control |
(0.7 - 6.6) KW with 0.1 KW resolution |
10 |
Reactive Power Control |
4 KVAr capacitive to 4 KVAr inductive |
10 |
Maximum Fault Current (A) |
15 A (per phase) |
11 |
Maximum Output Over Current Protection (A) |
15 A (per phase) |
Efficiency Data |
1 |
Maximum Efficiency |
98.3 % (@ 720 V PV Voltage and 4950 W operating solar power) |
2 |
Efficiency @ rated power, rated PV and Grid Voltage |
98.1% |
3 |
Euro Efficiency @ rated PV and Grid Voltage |
97.3% |
4 |
Euro Efficiency @ rated Grid Voltage (Averaged over PV voltage range) |
97.3% |
5 |
Static MPPT Efficiency (EN 50530) |
> 99.9 % |
6 |
Dynamic MPPT Efficiency (EN 50530) |
98.6% |
Protection |
1 |
Anti-islanding Protection |
Integrated |
2 |
Input Reverse Polarity Protection |
Integrated |
3 |
SPD AC Side |
350 Vac (per phase), Type-III SPD integrated |
4 |
SPD DC Side |
1000 Vdc (per PV string), Type-III SPD integrated |
5 |
Residual Current Monitoring Unit |
Integrated |
6 |
Output Over Current Protection |
Integrated |
7 |
Output Short Circuit Protection |
Integrated |
8 |
Grid Over Voltage Protection |
Integrated |
General Data |
1 |
Operating Temperature Range (◦C) |
-25 to +55 ◦C |
2 |
Relative Humidity |
(0 - 95) % |
3 |
Operating Altitude (m) |
<= 2000 m |
4 |
Cooling |
Natural Convection |
5 |
Noise (db) |
< 25 dB |
6 |
User Interface |
16 X 2 LCD & LED indications |
7 |
Remote Monitoring (Wifi and GSM both options integrated within inverter) |
Via Mobile App (both Android and IOS versions available) |
8 |
Inverter Weight (kg) |
20 kg |
9 |
Shipping Weight (kg) |
< 25 kg |
10 |
Size (Width x Height x Depth) mm3 |
(404 x 420 x 185) mm3 |
11 |
IP Protection |
IP 65 |
12 |
Night Self Consumption for control electronics (W) |
< 6 W |
13 |
Topology |
Transformer-less |
14 |
Protective Class |
Class I |
15 |
Grid Side Connector |
5-pin connector,650 V, 50 A, IP-67 |
16 |
PV Side Connectors |
MC4 Connectors, IP-67 |
Standards |
1 |
Safety Standard |
IS 1622 / IEC 62109-2 |
2 |
Anti-islanding |
IS 16169 / IEC 62116 |
3 |
Harmonic Current Control |
IEC 61000-3-2 |
4 |
Grid Under/Over Voltage Setting |
as per CEA India by default (under voltage settable upto 180(per phase) V) |
5 |
Grid Under/Over Frequency Setting |
as per CEA India |