2.5 kW Emergency Battery Charger
Specification No. EDTS 163

Features:
- Designed for 230 V AC, 1-phase input with 116 VDC output at 20 A max.
- High efficiency operation with >80% efficiency and ripple content under 3%.
- Built-in protections: Over-voltage (125 VDC ±1V), short circuit (trip at 24A), and IP-23 protection.
- Self-reset functionality: Charger auto-restarts once fault condition clears.
- Rugged CRCA enclosure with force air cooling, weighing less than 45 kg.
Technical Specifications :
| Input voltage | |
|---|---|
| Nominal voltage | 230 V AC, 1-phase |
| Operating range | 230 V AC ±5%, 50 Hz ±3% |
| Output (DC) | |
| Type | Fully insulated from coach body on both positive and negative sides |
| Output Voltage | 116 VDC ±1% |
| Output current | 20 A max |
| Efficiency | Greater than 80% at full load |
| Ripple content | Less than 3% |
| Protections | |
| O/P Over Voltage | 125 VDC ±1 V |
| Output Current | Limited to 20 A (trip at 24 A) |
| Self-reset feature | Restarts automatically when trip clears |
| IP Protection | IP-23 |
| Isolation | Galvanic isolation provided |
| Construction | |
| Enclosure | 1.6 mm thick CRCA |
| Overall Width | 525 mm |
| Overall Depth | 320 mm |
| Overall Height | 225 mm |
| Mounting | 475 × 288 mm |
| Weight | Less than 45 kg |
| Cooling | Forced air cooled |