Specification No. RDSO/PE/SPEC/AC/0183-2018 (Rev-1) & RDSO/PE/SPEC/AC/0183-2018 (Rev-1)


Features:

  • Natural-cooled IGBT/SiC based, DSP-controlled charger with keypad-settable voltage and current limiting
  • Dual-mode operation with 4.5 kW RBC in normal mode and 2.5 kW EBC backup in emergency mode
  • Built-in protections including over/under voltage, short-circuit, reverse polarity, earth leakage, and galvanic isolation
  • LED indications, RTC-based fault logging with 300+ events, and USB port for easy data download
  • Rugged IP65 stainless steel enclosure, vibration-tested, and designed for reliable underslung mounting on LHB coaches
Technical Specifications:
Ratings & I/O
RBC Input 415 V AC, 3-phase, 4-wire, 50 Hz; THD ≤ 10%
RBC Output 110–135 V DC (keypad-settable), 35 A max; Battery charge current 10–15 A (keypad-settable)
Battery Type 70/120 Ah lead-acid (flooded or VRLA)
EBC Input 240 V AC single-phase, 50 Hz
EBC Output 110 V ± 5% DC, 22 A, up to 2.5 kW
Operating Modes
Normal RBC feeds full 4.5 kW; EBC on standby
Emergency EBC auto-activates on RBC failure; feeds 2.5 kW at 110 V DC; “Emergency Mode ON” LED provided
Regulation, Efficiency & Ripple
Output Regulation 122 ± 2% V during normal charging across input/load range
Efficiency RBC ≥ 85% (½-load), ≥ 92% (full-load); EBC ≥ 90% (full-load)
Ripple (r.m.s.) RBC: Voltage ≤ 2%, Current ≤ 3%; EBC: Voltage ≤ 2% at full load
Environmental & Mechanical
Ambient Conditions −5 °C to +55 °C; RH up to 98%; vibration per IEC 61373 (≈ 3 g); altitude ≤ 1200 m
Enclosure IP-65 SS-304, 2.0 mm; natural cooling; under-slung mounting
Dimensions L: 900 mm (max), W: 600 mm (max), H: 650 mm (max); Mounting hole CTC L: 850 ±0.8, W: 300 ±0.5
Weight ≤ 120 kg
Protections
RBC Input O/V–U/V trip: 480 ±5 V / 300 ±5 V; withstand 510 V AC for 2 min; auto-reset
RBC Output O/V trip: 136 ±2 V; Current limit: 35 A total, 10–15 A battery (keypad-settable); 42 A overload
EBC Protection Input O/V & U/V at 240 V ±15%; Output current limit = 24 A
General Protection Reverse polarity, short-circuit protection; earth-leakage indication >≈30 mA; IP65 protection; galvanic isolation
Indications & Diagnostics
LED Indications R/Y/B, battery charging ON, single-phasing, +/− earth-leakage, battery not healthy, emergency mode ON
Diagnostics Fault log stores last ≥ 300 events with RTC; USB port for data download (FIFO, no deletion)
Construction Highlights
Industrial-grade electronics; FR-4 PCBs; SS hardware; H-class HF transformer with galvanic isolation; SS-304/S2 or SS-304/L enclosure; two M10 earthing pads