BIS Approved Single Phase Inverter 1.1 kW to 5.0 kW,


Features:

  • Advanced MPPT (Maximum Power Point Tracking) Technology
  • Low Standby Power Consumption
  • Robust and Durable Construction
  • Comprehensive Protection Mechanisms
  • User-Friendly Interface
  • Free of Cost 24×7 Remote Monitoring (Android/iOS/Web Application)
  • Highest Life Time of Product
  • Higher Efficiency (Up to 98%)
  • DC Oversizing (Up to 30%)
  • Silicon Carbides (SiC) Power Device Technology
General Data:
TECHNICAL DATA 3.3 KW 4 KW 5 KW 6 KW
Operating Temperature Range (°C) -25 to +55 °C
Relative Humidity (0 – 95)%
Operating Altitude (m) <= 2000 m
Cooling Natural Convection
Noise (db) < 25 dB
User Interface 16 x 2 LCD & LED indications
Remote Monitoring (WiFi & GSM options) Via Mobile App (both Android and iOS versions available)
Inverter Weight (Kg) 9 Kg 12 Kg 14 Kg
Shipping Weight (Kg) < 11 Kg < 15 Kg < 16 Kg
Size (W x H x D) mm³ (404 x 285 x 180) mm³ (470 x 300 x 180) mm³
IP Protection IP 65
Night Self Consumption for control electronics (W) < 4 W
Topology Transformer-less
Protective Class Class I
Grid Side Connector 3-pin Connector, 25A, IP-68
PV Side Connector MC4 Connector, IP-67
Efficiency Data:
DATA 3.3 KW 4 KW 5 KW 6 KW
Maximum Efficiency 97.7% (@ 720 V PV Voltage & 2475 W operation solar power) 97.7% (@ 720 V PV Voltage & 2475 W operation solar power) 97.8% (@ 720 V PV Voltage & 2.5 KW operation solar power) 98.2% (@ 720 V PV Voltage & 3.0 KW operation solar power)
Efficiency @ Rated Power, Rated PV and Grid Voltage 97.3% 97.4% 97.4% 97.7%
Euro Efficiency @ Rated PV and Grid Voltage 97.7% 96.5% 96.8% 97.2%
Euro Efficiency @ Rated Grid Voltage (Averaged over PV Voltage Range) 96.7% 96.5% 96.8% 97.2%
Static MPPT Efficiency (EN 50530) > 99.8%
Dynamic MPPT Efficiency (EN 50530) 98.8%
AC Output Data:
AC OUTPUT DATA 3.3 KW 4 KW 5 KW 6 KW
Rated Output Power (W) 3.3 KW 4 KW 5 KW 6 KW
Maximum Output Voltage Apparent Power (KVA) 4.5 KVA (@ maximum grid voltage of 264 V) 5.3 KVA (@ maximum grid voltage of 264 V) 6.6 KVA (@ maximum grid voltage of 264 V) 7.9 KVA (@ maximum grid voltage of 264 V)
Nominal Output Voltage/Range (V) 240/(204 – 264)V
Nominal Output Frequency/Range (Hz) 50/(47.5 – 52) Hz
Max. Continuous Output Current (A) 17 A 20 A 25 A 30 A
Current Inrush at inverter start-up (A) 15 A (Peak)
Output Power Factor Default unity (Adjustable from 0.8 Leading to 0.8 Lagging)
Output THD (@ Nominal Output Power and Voltage) < 2.0% < 1.8% < 1.5% < 1.25%
Active Power Control (0.3 – 3.3) KW with 0.1 KW resolution (0.4 – 4.0) KW with 0.1 KW resolution (0.5 – 5.0) KW with 0.1 KW resolution (0.6 – 6.0) KW with 0.1 KW resolution
Reactive Power Control 2.0 KVAr Capacitive to 2 KVAr Inductive 2.4 KVAr Capacitive to 2 KVAr Inductive 3 KVAr Capacitive to 3 KVAr Inductive 3.6 KVAr Capacitive to 3.6 KVAr Inductive
Maximum Fault Current (A) 22 A 26 A 32 A 38.4 A
Maximum Output Over Current Protection (A) 22 A 26 A 32 A 38.4 A
PV String Output Data:
TECHNICAL DATA 3.3 KW 4 KW 5 KW 6 KW
Maximum PV Power at STC (Standard Test Condition) 4.5 Kwp 5.3 Kwp 6.6 Kwp 7 Kwp
Recommended PV Power at STC (Standard Test Condition) 3.3-4.5 Kwp 4.0-5.3 Kwp 5.0-6.6 Kwp 5.5-7.0 Kwp
Vmax PV (absolute maximum) (V) 1000 V
MPPT Range (V) 80-800 V
MPPT Range for Full Load (V) 200-800 V 240-800 V 300-800 V 300-800 V
Start-up Voltage (V) Setable (100-500 V)
Nominal Input DC Voltage (V) 500 V 520 V 550 V 600 V
Max. Continuous Input Current (A) 17 A
Isc PV (absolute maximum short circuit current) (A) 20 A
No. of MPP Trackers 1
No. of Inputs Strings Per Tracker 1
Maximum Backfeed Current (A) 0 A
Protection:
1.1 KW – 5 KW
Anti-islanding protection Integrated
Input reverse polarity Protection Integrated
SPD AC Side 350 Vac, Type-III SPD Integrated
SPD DC Side 1000 Vdc, Type-III SPD Integrated
Residual Current Monitoring unit Integrated
Output Over Current protection Integrated
Output Short circuit protection Integrated
Grid Over Voltage protection Integrated
Standards:
1.1 KW – 5 KW
Safety Standard IS 16221 / IEC 62109-2
Anti-islanding IS 16169 / IEC 62116
Harmonic Current Control IEC 61000-3-2
Grid Under/Over Voltage Setting As per CEA India by default (under voltage settable up to 180 V (per phase))
Grid Under/Over Frequency Setting As per CEA India