BIS Approved Three Phase Inverter 5.0 kW to 15.0 kW


Features:

  • Advanced MPPT (Maximum Power Point Tracking) Technology
  • Low Standby Power Consumption
  • Robust and Durable Construction
  • Comprehensive Protection Mechanisms
  • User-Friendly Interface
  • Free of Cost 24×7 Remote Monitoring (Android/iOS/Web Application)
  • Highest Life Time of Product
  • Higher Efficiency (Up to 98%)
  • DC Oversizing (Up to 30%)
  • Silicon Carbides (SiC) Power Device Technology
General Data:
TECHNICAL DATA 5.0 KW 6.6 KW 8.8 KW 10.0 KW (2 MPPT) 10.0 KW 12.0 KW 15.0 KW
Operating Temperature Range (°C) -25 to +55 °C
Relative Humidity (0 – 95)%
Operating Altitude (m) <= 200 m
Cooling Natural Convection
Noise (db) < 25 dB
User Interface 16 x 2 LCD & LED indications
Remote Monitoring (WiFi & GSM options) Via Mobile App (both Android and iOS versions available)
Inverter Weight (Kg) 16 Kg 20 Kg 24 Kg 25 Kg 29 Kg
Shipping Weight (Kg) < 20 Kg < 25 Kg < 30 Kg < 32 Kg < 40 Kg
Size (W x H x D) mm³ (470 x 300 x 180) mm³ (404 x 420 x 185) mm³ (500 x 420 x 190) mm³ (600 x 420 x 185) mm³
IP Protection IP 65
Night Self Consumption for control electronics (W) < 6 W < 7 W
Topology Transformer-less
Protective Class Class I
Grid Side Connector 5-pin Connector, 650V, 25A, IP-67
PV Side Connector MC4 Connector, IP-67
Efficiency Data:
Rated Output Power 5 KW 6.6 KW 8.8 KW 10.0 KW (2 MPPT) 10.0 KW 12 KW 15 KW
Maximum Efficiency 98.2% @720V PV Voltage & 2475 W operating solar power 98.3% @720V PV Voltage & 4950 W operating solar power 98.5% @720V PV Voltage & 6600 W operating solar power 98.4% @720V PV Voltage & 6600 W operating solar power 98.5% @720V PV Voltage & 6600 W operating solar power 98.5% @720V PV Voltage & 9000 W operating solar power
Efficiency @ Rated power, Rated PV and Grid Voltage 98.1% 98.2% 98.1% 98.2%
Euro Efficiency @ Rated PV and Grid Voltage 97% 97.3% 97.7% 97.5% 97.1% 97.5%
Euro Efficiency @ Rated Grid Voltage (Averaged over PV voltage range) 99.9% 97.3% 97.6% 97.5% 97.1% 97.5%
Static MPPT Efficiency (EN 50530) >98.6%
Dynamic MPPT Efficiency (EN 50530) 98.6%
AC Output Data:
DATA 5 KW 6.6 KW 8.8 KW 10.0 (2 MPPT) 10.0 KW 12.0 KW 15.0 KW
Rated Output Power (W) 5 KW 6.6 KW 8.8 KW 10 KW 10 KW 12 KW 15 KW
Maximum Output Apparent Power (KVA) 6.6 KVA (@maximum grid voltage of 264 V) 8.8 KVA (@maximum grid voltage of 460 (1-1) V) 11.5 KVA (@maximum grid voltage of 460) 13.5 KVA (@maximum grid voltage of 460 (1-1) V) 16 KVA (@maximum grid voltage of 460 (1-1) V) 20 KVA (@maximum grid voltage of 460 (1-1) V)
Nominal Output/ Range (V) 415/(350 -460) V
Nominal Output Frequency / Range (Hz) 50/(47.5-52)Hz
Max. Continuous Output (A) 8.5 A (per phase) 11 A (per phase) 15 A (per phase) 17 A (per phase) 20 A (per phase) 25 A (per phase)
Current Inrush at inverter start-up (A) 10 A (peak) 15 A (peak)
Output Power Factor Default unity (Adjustable from 0.8 Leading to 0.8 Lagging)
Output THD (@ Nominal Output Power of Voltage) < 3% < 2.5% < 2% < 1.8% < 1.7% < 1.6% < 1.5%
Active Power Control (0.5 – 5) KW with 0.1 KW resolution (0.7 – 6.6) KW with 0.1 KW resolution (0.9 – 8.8) KW with 0.1 KW resolution (1.1 – 10) KW with 0.1 KW resolution (1.2 – 12) KW with 0.1 KW resolution (1.5 – 15) KW with 0.1 KW resolution
Reactive Power Control 3 KVAr capacitive to 3 KVAr inductive 4 KVAr capacitive to 4 KVAr inductive 5.3 KVAr capacitive to 5.3 KVAr inductive 6 KVAr capacitive to 6 KVAr inductive 7.2 KVAr capacitive to 7.2 KVAr inductive 9 KVAr capacitive to 9 KVAr inductive
Maximum Fault Current (A) 11 A (per phase) 15 A (per phase) 20 A (per phase) 22 A (per phase) 26 A (per phase) 32 A (per phase)
Maximum Output Over Current Protection (A) 11 A (per phase) 15 A (per phase) 20 A (per phase) 22 A (per phase) 26 A (per phase) 32 A (per phase)
PV String Output Data:
TECHNICAL DATA 5.0 KW 6.6 KW 8.8 KW 10.0 (2 MPPT) 10.0 KW 12.0 KW 15.0 KW
Maximum PV Power at STC (Standard Test Condition) 6.6 KWp 8.8 KWp 11.5 KWp 13.5 KWp 16 KWp 20 KWp
Recommended PVPSTC (Standard Test Condition) 5-6.6 KWp 6.6-8.8 KWp 8.8-11.5 KWp 10-13.5 KWp 12-16 KWp 15-20 KWp
Vimax PV absolute maximum (V) 1000 V
MPPT Range V 80-800 V
MPPT Range for Full Load V 300-800 V 200-800 V 260-800 V 300-800 V 200-800 V 240-800 V 300-800 V
Start-up Voltage (V) Settable (100-500V)
Nominal Input DC Voltage (V) 550 V
Max. continuous input cant (A) 17 A
Isc PV (absolute maximum short circuit current (A) 20 A (per PV string)
No. of MPP Trackers 1 2 3
No. of Input Strings per Tracker 1
Maximum Backed Current (A) 0A
Protection:
5 KW – 15 KW
Anti-islanding protection Integrated
Input reverse polarity Protection Integrated
SPD AC Side 350 Vac, Type-III SPD Integrated
SPD DC Side 1000 Vdc, Type-III SPD Integrated
Residual Current Monitoring unit Integrated
Output Over Current protection Integrated
Output Short circuit protection Integrated
Grid Over Voltage protection Integrated
Standards:
5 KW – 15 KW
Safety Standard IS 16221 / IEC 62109-2
Anti-islanding IS 16169 / IEC 62116
Harmonic Current Control IEC 61000-3-2
Grid Under/Over Voltage Setting As per CEA India by default (under voltage settable up to 180 V (per phase))
Grid Under/Over Frequency Setting As per CEA India